Search form

Languages

SAR 1

The SAR 1 is connected to a telecommunications line and controlled by the call voltage.The SAR 1 only reacts to the call voltage, not to dialing pulses (IWV). It activates an external signal emitter with its own or separate power supply (e.g. bell, horn, or lamp) by means of a contact.The incorporated switch can be used to activate and deactivate external signals.

Input / call voltage 32 to 80 V AC
Input / frequency range 23 to 54 Hz
Input / impedance 10 kOhm at 75 V, 25 Hz
Input / insertion loss less than 0.5 dB
Input / leakage resistance more than 5 MOhm at 100 V
Output / switching current max. 8 A
Output / continuous current max. 6 A
Output / switching voltage max. 250 V AC
Output / switching capacity 2000 VA (AC)
240 W (less than 30 V DC)
50 W (greater than 30 V DC)
Electrical safety acc. to EN 60950
Dimensions (W x H x D) 65 x 80 x 27 mm
Operating temperature range -5 °C to + 55 °C
Storage temperature range -25 °C to + 70 °C

Technical Data 

  • P/N130280-I
    Colorwhite
    EAN-No4250184101673

Downloads

pdf Instruction 130280-I 268.3 KB
last update on Tuesday, 11. July 2017 - 7:12